Clean Air Feed Systems
Teknopak offers a range of modules that feature HEPA filters to provide Class ISO 5 (Fed Std 209E Class 100) quality of air infeed:
Employing contemporary technologies in microcontamination control, all Teknopak units bear the hallmark of committed professionalism, and promise you quality, security, protection and full-value-for-money. Backed by rich experience, continuing research and strong infrastructure, Teknopak’s cost-performance-benefit equations remain unequaled.
Choose Teknopak; and you can be sure you are investing in the best in the market.

|
Ceiling Suspended Clean Air Feed Module (Standard Box Version) |
|||||
|
Model |
HEPA Filer Face Area |
Overall dimensions |
|||
|
w |
d |
W |
D |
H |
|
|
2252-CS |
24" |
24" |
28" |
30" |
32" |
|
2253-CS |
36" |
24" |
40" |
30" |
32" |
|
2254-CS |
48" |
24" |
52" |
30" |
32" |
|
2256-CS |
72" |
24" |
76" |
30" |
32" |
|
Execution |
||
|
Standard execution |
Optional features |
Typical applications |
|
|
|

|
Ceiling Suspended Clean Air Feed Module (Slim Box Version) |
|||||
|
Model |
HEPA Filer Face Area |
Overall dimensions |
|||
|
w |
d |
W |
D |
H |
|
|
2252-CS-SV |
24" |
24" |
28" |
50" |
20" |
|
2253-CS-SV |
36" |
24" |
40" |
50" |
20" |
|
2254-CS-SV |
48" |
24" |
52" |
50" |
20" |
|
2256-CS-SV |
72" |
24" |
76" |
50" |
20" |
|
Execution |
||
|
Standard execution |
Optional features |
Typical applications |
|
|
|

|
Floor-standing Clean Air Feed Module (Inclinable & Height-adjustable Version) |
|||||
|
Model |
HEPA Filer Face Area |
Overall dimensions |
|||
|
w |
d |
W |
D |
H |
|
|
2202-IH |
24" |
24" |
28" |
50" |
88" |
|
2203-IH |
36" |
24" |
40" |
50" |
88" |
|
2204-IH |
48" |
24" |
52" |
50" |
88" |
|
2206-IH |
72" |
24" |
76" |
50" |
88" |
|
Execution |
||
|
Standard execution |
Optional features |
Typical applications |
|
|
|

|
Clean Air Feed Module to build & sustain overpressure (Wall-mounted Version) |
||||||
|
Model |
Capacity |
Flange dimensions |
Overall dimensions |
|||
|
w |
d |
W |
D |
H |
||
|
2500 |
150 |
19" |
19" |
16" |
28" |
16" |
|
2501 |
250 |
31" |
19" |
28" |
28" |
16" |
|
2502 |
400 |
31" |
25" |
28" |
30" |
22" |
|
2503 |
500 |
31" |
31" |
28" |
30" |
28" |
|
2504 |
750 |
31" |
31" |
28" |
32" |
28" |
|
2505 |
1000 |
31" |
31" |
28" |
35" |
28" |
Notes:
1. Cut-out should be 1/4" larger than corresponding W, H
2. For floor mounting: 24" from floor level if fitted from outside; 5" from floor level is fitted from inside the room
|
Execution |
||
|
Standard execution |
Optional features |
Typical applications |
|
|
|

| Clean Air Feed Module for Sterilisers | |||||
|
Model |
Capacity |
Overall dimensions |
|||
|
W |
D |
D1 |
H |
||
|
2521 |
250 |
28" |
18" |
5" |
28" |
|
2522 |
400 |
28" |
18" |
5" |
42" |
|
2523 |
500 |
28" |
20" |
5" |
50" |
|
Execution |
||
|
Standard execution |
Optional features |
Typical applications |
|
|
|
|
Special Components |
|
|
Prefilter |
Washable, reusable fire-retardant depth filter, specially treated to inhibit microfloral growth |
|
HEPA filter |
Microfibreglass media. Efficiency > 99.97% down to 0.3 m at both 100% & 20% of rated airflow |
|
Impellers |
Statically and dynamically balanced for high performance, low noise and vibration |
|
Blower-motor |
Direct-driven dual outlet design with special sealed bearings and unique suspension |
|
Tech-brief |
|
|
Governing standards |
ISO 14644 (1998) |
|
Air velocity |
90 fpm (0.45 mps) +/- 20% (where applicable |
|
Cleanliness level |
Fewer than 100 particles of size 0.5 m or larger per cu.ft of air sampled ( or <3,520/cuM ) at filter face |
|
Noise level |
< 65 dB (A Scale) |
|
Vibration level |
< 2.5 m (0.0001") |
|
Electricals |
230V AC, 1 f, 50 Hz |
![]() |